Glasswool Wall & Floor SupaBatts Data SheetProduct Description
Glasswool Wall & Floor SupaBatts have a special treatment added to increase their ability to repel water which gives added protection to internal walls from possible water damage. Glasswool Wall & Floor SupaBatts will not burn and will provide excellent thermal and acoustic insulation in the home. ApplicationGlasswool Wall & Floor SupaBatts are manufactured to a controlled thickness so that installation in walls can be achieved without the insulation contacting the external walls. Glasswool Wall & Floor SupaBatts should be retained in position with string so that ventilation of the wall cavity is preserved. Glasswool Wall& Floor SupaBatts will both increase comfort and reduce energy bills in the home by keeping heat out during summer and heat in during winter. Glasswool Wall & Floor SupaBatts will also reduce noise entering the home when installed in the external walls, or reduce noise transfer between rooms when installed in the internal walls. Glasswool Wall & FloorSupaBatts are supplied in two convenient widths to suit standard housing construction: 430mm width for450mm stud centres, and 580mm width for 600mm stud centres. For safe handling instructions please refer to MSDS sheet. Standard Sizes and PackagingGlasswool Wall & Floor SupaBatts are packed in strong, tear resistant & sealed clear polythene plastic bags with labels inserted for easy identification. The standard sizes and R-values are listed below:
Factory Applied FacingsThe product is not usually supplied with factory applied facings, however, non standard products can be manufactured subject to minimum order quantities. Maximum Service TemperatureMaximum service temperature: 350°C. The product is intended for use at temperatures normally prevailing in building structures. Fire ResistanceWhen tested in accordance with AS/NZS 1530.3:1999, Glasswool Wall & Floor SupaBatts have the following Early Fire Hazard Indices:
Corrosion ResistanceGlasswool Wall & Floor Batts are faintly alkaline and incapable of corroding steel. To maintain this condition, protection must be provided against contamination from external sources. When tested in accordance with BS 3958: Part 5-1969, Wall & Floor Batts have a pH of 7.5-8.0. Moisture ResistanceExposure to an atmosphere of 50°C and 95% relative humidity for four days, results in moisture absorption of less than 0.2% by volume. Flow Resistivity0.5 x 104mks Rayls/m. Sound AbsorptionWhen tested in a reverberation chamber in accordance with AS 1045-1988 the sound absorption coefficients shown in the table were measured. Product Facing Thickness Frequency (Hz) |
|||||||||||||||||||
|